| Model |
| Brand | Tripp Lite |
| Tripp Lite | SMART1500LCD |
| OUTPUT |
| Output Volt Amp Capacity (VA) |
1500 |
| Output kVA capacity (kVA) |
1.5 |
| Output Watt Capacity (watts) |
900 |
| Nominal Output Voltage(s) Supported |
115V; 120V |
| Frequency compatibility |
60 Hz |
| Output voltage regulation (line mode) |
-18%, +8% |
| Output voltage regulation (Battery mode) |
115V (+/- 5%) |
| Built-in UPS output receptacles |
8 5-15R outlet(s) |
| Output AC waveform (AC mode) |
Sine wave |
| Output AC waveform (battery mode) |
PWM sine wave |
| INPUT |
| Rated input current (at maximum load) |
8.5A |
| Nominal Input Voltage(s) Supported |
120V AC |
| UPS input connection type |
5-15P |
| Input circuit breaker |
10A |
| UPS Input cord length (ft.) |
6 |
| UPS Input cord length (m) |
1.8 |
| Recommended Electrical Service |
15A 120V |
| Phase |
Single-Phase |
| BATTERY |
| Full load runtime (minutes) |
3.5 min. (900w) |
| Half load runtime (minutes) |
13 min. (450w) |
| DC system voltage (VDC) |
24 |
| Battery recharge rate (included batteries) |
Less than 4.5 hours from 10% to 90% |
| VOLTAGE REGULATION |
| Voltage regulation description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
| Overvoltage correction |
Input voltages between 128 and 147 are reduced by 12% |
| Undervoltage correction |
Input voltages between 93 and 107 are boosted by 14% |
| Severe undervoltage correction |
Input voltages between 75 and 92 are boosted by 30% |
| LEDS ALARMS AND SWITCHES |
| LED Indicators |
Front panel LCD display |
| Front panel LCD display |
Backlighted LCD screen indicates input voltage, 5-bar battery charge
level, overload, AVR, on battery and replace battery status; LCD screen
rotates for rack/tower viewing |
| Alarms |
Audible alarm indicates power-failure and low-battery conditions |
| Alarm cancel operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness |
| SURGE / NOISE SUPPRESSION |
| UPS AC suppression joule rating |
480 |
| UPS AC suppression response time |
Instantaneous |
| UPS Dataline suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| EMI / RFI AC noise suppression |
Yes |
| PHYSICAL |
| Installation form factors supported with included accessories |
Tower |
| Included mounting accessory description |
Pair of mounting ears enable tower and 2-4 post rackmount installation |
| Primary form factor |
Rackmount |
| UPS / Power Module dimensions in primary form factor (height x width x depth / inches) |
3.5 x 17.3 x 10.5 |
| UPS / Power Module dimensions in primary form factor (height x width x depth / cm) |
8.9 x 43.8 x 26.7 |
| Installed whole system dimensions in secondary form factor (height x width x depth / cm) |
43.8 x 8.9 x 26.7 |
| Installed whole system maximum rack depth (inches) |
10.5 |
| Installed whole system maximum rack depth (cm) |
26.7 |
| Rack Height |
2U |
| Secondary form factor |
Tower |
| Installed whole system dimensions in secondary form factor (height x width x depth / inches) |
17.3 x 3.5 x 10.5 |
| UPS dimensions in secondary form factor (height x width x depth / cm) |
43.8 x 8.9 x 26.7 |
| UPS / Power Module weight (lbs) |
29.4 |
| UPS / Power Module weight (kg) |
13.3 |
| UPS Shipping dimensions (height x width x depth / inches) |
7.5 x 15 x 21.5 |
| UPS Shipping dimensions (height x width x depth / cm) |
19 x 38.1 x 54.6 |
| Shipping weight (lbs) |
33.4 |
| Shipping weight (kg) |
15.2 |
| Cooling method |
Fan |
| UPS housing material |
ABS |
| ENVIRONMENTAL |
| Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity |
0 to 95%, non-condensing |
| AC mode BTU / hr. (full load) |
255 |
| AC mode efficiency rating (100% load) |
92% |
| COMMUNICATIONS |
| Communications interface |
USB (HID enabled) |
| Network monitoring port description |
Supports detailed monitoring of UPS and site power conditions |
| PowerAlert software |
Free download from www.tripplite.com |
| Communications cable |
USB interface cable included |
| WatchDog compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| LINE / BATTERY TRANSFER |
| Transfer time |
4 milliseconds |
| Low voltage transfer to battery power (setpoint) |
75 |
| High voltage transfer to battery power (setpoint) |
147 |
| SPECIAL FEATURES |
| Cold Start (startup in battery mode during a power failure) |
Cold-start operation supported |
| CERTIFICATIONS |
| UPS Certifications |
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
| WARRANTY |
| Product Warranty Period (U.S. & Canada) |
3-year limited warranty |
| Product Warranty Period (Latin America) |
3-year limited warranty |
| Product Warranty Period (International) |
2-year limited warranty |
| Product Warranty Period (Mexico) |
3-year limited warranty |